fixed bug with sensor names and types

development
Thiemann96 5 years ago
parent 28baa05d78
commit e02014cb78

@ -13,19 +13,20 @@
<ion-list> <ion-list>
<ion-item> <ion-item>
<ion-label floating>Typ</ion-label> <ion-label floating>Phenomenon</ion-label>
<ion-select [(ngModel)]="typ"> <ion-select [(ngModel)]="typ">
<ion-option value="HDC1080">HDC1080(Air temperature & relative humidity)</ion-option> <ion-option value="HDC1080">Air temperature</ion-option>
<ion-option value="BMP280">BMP280(Air pressure)</ion-option> <ion-option value="HDC1080_r">Relative humidity</ion-option>
<ion-option value="TSL45315">TSL45315(Lux)</ion-option> <ion-option value="BMP280">Air pressure</ion-option>
<ion-option value="VEML6070">VEML6070(UV)</ion-option> <ion-option value="TSL45315">Lux</ion-option>
<ion-option value="SMT50">SMT50</ion-option> <ion-option value="SDS1001">Particulate Matter 10</ion-option>
<ion-option value="SOUNDLEVELMETER">SOUNDLEVELMETER</ion-option> <ion-option value="SDS1001_r">Particulate Matter 2.5</ion-option>
<ion-option value="BME680">BME680</ion-option> <ion-option value="SMT50">Soil moisture</ion-option>
<ion-option value="VEML6070">UV Intensity</ion-option>
<ion-option value="SOUNDLEVELMETER">Sound level</ion-option>
<ion-option value="BME680">Air quality</ion-option>
</ion-select> </ion-select>
</ion-item> </ion-item>
<ion-item> <ion-item>
<ion-label floating>Sensor ID</ion-label> <ion-label floating>Sensor ID</ion-label>
<ion-input type="text" [(ngModel)]="id"></ion-input> <ion-input type="text" [(ngModel)]="id"></ion-input>

@ -59,7 +59,9 @@ export class ConfigurationPage {
switch (sensor.typ) { switch (sensor.typ) {
case "HDC1080": case "HDC1080":
values["TEMPERSENSOR_ID"] = sensor.id values["TEMPERSENSOR_ID"] = sensor.id
values["RELLUFSENSOR_ID"] = sensor.id2 break;
case "HDC1080_r":
values["RELLUFSENSOR_ID"] = sensor.id
break; break;
case "BMP280": case "BMP280":
values["LUFTDRSENSOR_ID"] = sensor.id values["LUFTDRSENSOR_ID"] = sensor.id
@ -71,10 +73,10 @@ export class ConfigurationPage {
values["UVINTESENSOR_ID"] = sensor.id values["UVINTESENSOR_ID"] = sensor.id
break; break;
case "SDS1001": case "SDS1001":
values["PM10SENSORID"] = sensor.id values["PM10SENSOR_ID"] = sensor.id
values["PM25SENSOR_ID"] = sensor.id2
break; break;
case "SDS1001_r":
values["PM25SENSOR_ID"] = sensor.id
default: default:
break; break;
} }